Changeset 9820


Ignore:
Timestamp:
09/16/11 10:29:16 (14 years ago)
Author:
seroussi
Message:

some displays

Location:
issm/trunk/src/m/classes
Files:
4 edited

Legend:

Unmodified
Added
Removed
  • issm/trunk/src/m/classes/groundingline.m

    r9811 r9820  
    6969
    7070                        fielddisplay(obj,'migration','type of grounding line migration: ''SoftMigration'',''AgressiveMigration'' or ''None''');
    71                         fielddisplay(obj,'melting_rate','');
     71                        fielddisplay(obj,'melting_rate','melting rate applied when previously grounded parts start floating');
    7272
    7373                end % }}}
  • issm/trunk/src/m/classes/hydrology.m

    r9739 r9820  
    5252
    5353                end % }}}
     54                function disp(obj) % {{{
     55                        disp(sprintf('   hydrology solution parameters:'));
     56
     57                        fielddisplay(obj,'spcwatercolumn','water thickness constraints (NaN means no constraint)');
     58                        fielddisplay(obj,'n','Manning roughness coefficient');
     59                        fielddisplay(obj,'CR','turtuosity parameter');
     60                        fielddisplay(obj,'p','dimensionless exponent in Manning velocity formula');
     61                        fielddisplay(obj,'q','dimensionless exponent in Manning velocity formula');
     62                        fielddisplay(obj,'kn','parameter in effective pressure formula');
     63                        fielddisplay(obj,'stabilization','0->no, 1->artificial_diffusivity');
     64
     65                end % }}}
    5466        end
    5567end
  • issm/trunk/src/m/classes/initialization.m

    r9739 r9820  
    4444
    4545                end % }}}
     46                function disp(obj) % {{{
     47                        disp(sprintf('   initial field values:'));
     48
     49                        fielddisplay(obj,'vx','x component of velocity');
     50                        fielddisplay(obj,'vy','y component of velocity');
     51                        fielddisplay(obj,'vz','z component of velocity');
     52                        fielddisplay(obj,'vel','velocity norm');
     53                        fielddisplay(obj,'pressure','pressure field');
     54                        fielddisplay(obj,'temperature','temperature in Kelvins');
     55                        fielddisplay(obj,'watercolumn','thickness of subglacial water');
     56                        fielddisplay(obj,'waterfraction','fraction of water in the ice');
     57
     58                end % }}}
    4659        end
    4760end
  • issm/trunk/src/m/classes/inversion.m

    r9783 r9820  
    145145                        fielddisplay(obj,'iscontrol','is inversion activated?');
    146146                        fielddisplay(obj,'control_parameters','parameter where inverse control is carried out; ex: {''FrictionCoefficient''}, or {''RheologyBbar''}');
    147                         fielddisplay(obj,'cost_functions_coefficients','cost_functions_coefficients applied to the misfit of each node');
     147                        fielddisplay(obj,'cost_functions_coefficients','cost_functions_coefficients applied to the misfit of each vertex and for each control_parameter');
    148148                        fielddisplay(obj,'nsteps','number of optimization searches');
     149                        fielddisplay(obj,'maxiter_per_step','maximum iterations during each optimization step');
     150                        fielddisplay(obj,'cost_functions','indicate the type of response for each optimization steps');
    149151                        fielddisplay(obj,'cost_function_threshold','misfit convergence criterion. Default is 1%, NaN if not applied');
    150152                        fielddisplay(obj,'gradient_scaling','scaling factor on gradient direction during optimization, for each optimization step');
    151                         fielddisplay(obj,'cost_functions','indicate the type of response for each optimization steps');
    152                         fielddisplay(obj,'maxiter_per_step','maximum iterations during each optimization step');
    153153                        fielddisplay(obj,'step_threshold','decrease threshold for misfit, default is 30%');
    154                         fielddisplay(obj,'min_parameters','absolute minimum acceptable value of the inversed parameter');
    155                         fielddisplay(obj,'max_parameters','absolute maximum acceptable value of the inversed parameter');
     154                        fielddisplay(obj,'min_parameters','absolute minimum acceptable value of the inversed parameter on each vertex');
     155                        fielddisplay(obj,'max_parameters','absolute maximum acceptable value of the inversed parameter on each vertex');
    156156                        fielddisplay(obj,'gradient_only','stop control method solution at gradient');
     157                        fielddisplay(obj,'num_control_parameters','number of control_parameters');
     158                        fielddisplay(obj,'num_cost_functions','number of cost_functions');
    157159                        fielddisplay(obj,'vx_obs','observed velocity x component [m/a]');
    158160                        fielddisplay(obj,'vy_obs','observed velocity y component [m/a]');
    159161                        fielddisplay(obj,'vel_obs','observed velocity magnitude [m/a]');
     162                        fielddisplay(obj,'thickness_obs','observed thickness [m]');
    160163                        disp('Available responses:');
    161164                        disp('   101: SurfaceAbsVelMisfit');
Note: See TracChangeset for help on using the changeset viewer.