Index: /issm/trunk-jpl/src/m/classes/thermal.py
===================================================================
--- /issm/trunk-jpl/src/m/classes/thermal.py	(revision 27521)
+++ /issm/trunk-jpl/src/m/classes/thermal.py	(revision 27522)
@@ -43,4 +43,5 @@
         s += '{}\n'.format(fielddisplay(self, 'isdrainicecolumn', 'wether waterfraction drainage is enabled for enthalpy formulation (default is 1)'))
         s += '{}\n'.format(fielddisplay(self, 'watercolumn_upperlimit', 'upper limit of basal watercolumn for enthalpy formulation (default is 1000m)'))
+        s += '{}\n'.format(fielddisplay(self, 'fe', 'Finite Element type: ''P1'' (default), ''P1xP2'''))
         s += '{}\n'.format(fielddisplay(self, 'requested_outputs', 'additional outputs requested'))
         return s
@@ -93,6 +94,7 @@
         if ('ThermalAnalysis' not in analyses and 'EnthalpyAnalysis' not in analyses) or (solution == 'TransientSolution' and not md.transient.isthermal):
             return md
-        md = checkfield(md, 'fieldname', 'thermal.stabilization', 'numel', [1], 'values', [0, 1, 2])
+        md = checkfield(md, 'fieldname', 'thermal.stabilization', 'numel', [1], 'values', [0, 1, 2, 3])
         md = checkfield(md, 'fieldname', 'thermal.spctemperature', 'Inf', 1, 'timeseries', 1)
+        md = checkfield(md,'fieldname', 'thermal.fe', 'values', ['P1', 'P1xP2', 'P1xP3'])
         md = checkfield(md, 'fieldname', 'thermal.requested_outputs', 'stringrow', 1)
         if 'EnthalpyAnalysis' in analyses and md.thermal.isenthalpy and md.mesh.dimension() == 3: