Changeset 14753


Ignore:
Timestamp:
04/25/13 09:05:43 (12 years ago)
Author:
bdef
Message:

BUG: fixed a test in gia classe

Location:
issm/trunk-jpl/src/m/classes
Files:
2 edited

Legend:

Unmodified
Added
Removed
  • issm/trunk-jpl/src/m/classes/gia.m

    r14724 r14753  
    2222                function md = checkconsistency(obj,md,solution,analyses) % {{{
    2323                 
    24                         if ~ismember(HydrologyAnalysisEnum(),analyses), return; end
     24                        if ~ismember(GiaAnalysisEnum(),analyses), return; end
    2525                        md = checkfield(md,'gia.lithosphere_thickness','NaN',1,'size',[md.mesh.numberofvertices 1],'>',0);
    2626
  • issm/trunk-jpl/src/m/classes/hydrologydc.m

    r14744 r14753  
    5757                        md = checkfield(md,'hydrology.sediment_transmitivity','>',0,'numel',1);
    5858                        md = checkfield(md,'hydrology.water_compressibility','>',0,'numel',1);
    59                        
    60                         md = checkfield(md,'hydrology.spcepl_head','forcing',1);
    61                         md = checkfield(md,'hydrology.epl_compressibility','>',0,'numel',1);
    62                         md = checkfield(md,'hydrology.epl_porosity','>',0,'numel',1);
    63                         md = checkfield(md,'hydrology.epl_thickness','>',0,'numel',1);
    64                         md = checkfield(md,'hydrology.epl_transmitivity','>',0,'numel',1);
    65                         md = checkfield(md,'hydrology.isefficientlayer','numel',[1],'values',[0 1]);
    66                        
     59
     60                        if obj.isefficientlayer==1,
     61                               
     62                                md = checkfield(md,'hydrology.spcepl_head','forcing',1);
     63                                md = checkfield(md,'hydrology.epl_compressibility','>',0,'numel',1);
     64                                md = checkfield(md,'hydrology.epl_porosity','>',0,'numel',1);
     65                                md = checkfield(md,'hydrology.epl_thickness','>',0,'numel',1);
     66                                md = checkfield(md,'hydrology.epl_transmitivity','>',0,'numel',1);
     67                                md = checkfield(md,'hydrology.isefficientlayer','numel',[1],'values',[0 1]);
     68            end
    6769                end % }}}
    6870                function disp(obj) % {{{
     
    7779                        fielddisplay(obj,'water_compressibility','water compressibility [Pa^-1]');
    7880
    79                         if isefficientlayer==1,
     81                        if obj.isefficientlayer==1,
    8082                                disp(sprintf('   - for the epl layer'));
    8183                               
Note: See TracChangeset for help on using the changeset viewer.